====== Test Points and Probes ====== One way of probing a circuit with an oscilloscope is to add an RF connector to the board and use a transmission line probe. Oscilloscope should then have 50 ohm termination, and board needs suitable series resistance. 950R on board with 50R on scope gives a 20:1 probe.