Line 1: | Line 1: | ||
- | ===== ACS758 | + | ====== Current Measurement ====== |
- | Suitable for high current, high or low side, measurement where isolation is needed. Noise limits low current performance. | + | ===== Nordic Power Profiler Kit II ===== |
- | [[https://www.allegromicro.com/-/media/ | + | [[https://infocenter.nordicsemi.com/pdf/PPK2_User_Guide_v1.0.1.pdf|Manual]] |
+ | == Limits == | ||
+ | * Max V: 5.5V | ||
+ | * Max I (measured): 1A | ||
+ | * Max I (sourced): 600mA | ||
+ | |||
+ | == Accuracy == | ||
+ | |||
+ | * < 50mA: ± 10% and ± 2% offset | ||
+ | * >= 50mA: ± 15% offset ± 5% | ||
+ | |||
+ | == Qs == | ||
+ | |||
+ | * Is it robust to output overcurrent or overvoltage? | ||
+ | * What does LED mean? | ||
+ | |||
+ | == Log == | ||
+ | |||
+ | 25 April 2024 | ||
+ | |||
+ | I connected it to a faulty device which drew too much current. The ppk2 firmware crashed as soon as power was switched on, and the device disconnected from USB. It seems like it does not have any overcurrent protection. A forum post said the sense resistors were damaged by overcurrent, | ||
+ | |||
+ | == Misc == | ||
+ | |||
+ | There is a third party python API: [[https:// | ||
+ | |||
+ | Forum post about using it: [[https:// | ||
+ | |||
+ | ===== INA3221 ===== | ||
+ | |||
+ | * I2C output, 3 channel amplifier. | ||
+ | * Max 26V. | ||
+ | * 350 μA consumption (quiescent though - working unspecified) | ||
+ | * 13 bit ADC. 40uV resolution on current sense. | ||
+ | * VSHUNT Shunt voltage input –163.84 to 163.8 mV. Quite limiting. | ||
+ | * [[https:// | ||
+ | * [[https:// | ||
+ | * Supply 2.7V - 5.5V | ||
+ | |||
+ | ==== Aliexpress devboard notes ==== | ||
+ | |||
+ | * Rs: 2W, 1%, 100mOhm. | ||
+ | * Solder jumpers connect a chosen pin to A0 to set I2C address. | ||
+ | * Voltages are measured from -ve sense pins. | ||
+ | * VS: Supply voltage | ||
+ | * VPU: Pullup voltage for power valid function | ||
+ | * TC: Timing control alert. Used for power sequencing test. | ||
+ | * Board has 10k i2c pullups | ||
+ | |||
+ | 100mR shunts gives max measurable current of 1638mA. I think it shouldn' | ||
+ | |||
+ | {{: | ||
+ | |||
+ | ===== ACS758 ===== | ||
+ | |||
+ | Suitable for high current, high or low side, measurement where isolation is needed. Noise limits low current performance. | ||
* Hall effect | * Hall effect | ||
Line 16: | Line 71: | ||
* 2% typ total error | * 2% typ total error | ||
* Zero current output is half Vcc. | * Zero current output is half Vcc. | ||
+ | |||
+ | [[https:// | ||
LCB-050B variant: | LCB-050B variant: | ||
- | +-50A, 40mV/A. | + | +-50A, 40mV/ |
There are higher current variants. | There are higher current variants. |